Automate
Run Interface Events Sequentially
To run Interface events sequentially in Automate:
- Create a validation view in the Data Source ID used for the interface.
- Select Interfaces in the Navigation pane.
- Click the Events icon for the desired interface.
- Click the Validations icon for the event that needs to wait until the previous event is done.
-
Click Add.
View the field description for the Interface Event (Validations) page
- Enter a value in the Priority field.
- Select View from the VALIDATION TYPE list box.
- Select Validation from the VALIDATION PURPOSE list box. This means that if the view returns a value, then the validation has failed.
- Select Pre from the VALIDATION WHEN list box to indicate the validation runs before the event runs.
- Select Retry from the DISPOSITION list box to indicate that if the validation fails, the interface waits and retries running the validation.
-
Click Save; the Vertical View displays.
View the field description for the Interface Event (Validations) page’s Vertical View
- Enter a descriptive comment in the Comment field.
- Click Save.
- Return to the Interface Events page.
- Click Vertical View for the event.
- Click Retry Parameters to expand the section.
-
Click Edit.
View the field description for the Interface Event page’s Vertical View
- Enter 10 in the Retry Interval field to indicate the stored procedure will retry 10 times.
- Enter 60 in the Maximum Retry Interval field.
-
Select Seconds from the Retry Interval UOM list box.
NOTE: This means that when the stored procedure fails, the DSP will try to run it again in 60 seconds for 10 times and then stop.
- Click Save.